Value Name | Data Type | Value Data |
---|---|---|
AssignRolesToNewWA |
DWORD |
If this value is 1, enables prompt to assign roles when creating a new work area. If this value is 0, disables prompt. 1 in PowerUser, 0 for Office client. |
NEW
AutoExpandOnDrag |
DWORD |
If this value is 1, causes folders to automatically expand when a document is dragged over them. If this value is 0 (default), the folders do not automatically expand. |
BriefCaseCache |
DWORD |
Location of temporary folder for external format briefcases. If this value is not set (default), uses default temporary directory (%TEMP% environment variable). |
NEW
BriefCaseOpenFormat |
String |
Default briefcase metadata format created on 32-bit computers. The default is XML (always on 64-bit computers). Set this value to .mdb to store the metadata in Access format. |
ContextHelpEnabled |
DWORD |
If this value is 1, enables the context-sensitive Help in client applications. If this value is 0 (default), context-sensitive Help is cleared. |
CopyFiles |
DWORD |
If this value is 1 (default), enables Duplicator’s Copy Inventor drawings and… option. |
CreateThumbnailOn |
DWORD |
Sum of bit flags indicating when to update thumbnails. 1 On import |
dbgEnableScriptDebugger |
DWORD |
If this value is 0, do not display the Script Debugger item on the Tools menu of PowerUser. If this value is 1, show the Script Debugger item if a script debugger is installed. Configured in the PowerUser Options dialog. |
DebugMode |
DWORD |
Sum of bit flags that specify debug levels. For internal use only. |
clearedColor |
DWORD |
Color to display document names in the view pane for documents that reside in a different work area. |
DisableMenuWF |
DWORD |
If this value is 1, disables the Workflow menu in PowerUser. If this value is 0 (default), enables the menu. |
DisableOfflineSwitch |
DWORD |
If this value is 1, disable Offline mode switch in Application Integration. If this value is 0 (default), do not disable Offline mode. See Disabling offline mode. |
DisableVaultShortcuts |
DWORD |
If this value is 0 (default), the Create Shortcut to This Vault command is enabled. If this value is 1, the command is cleared for the current user. Note This setting must be 0 for the command to be enabled if a scope is active and the command is enabled for that scope. |
DisplayManualReferences |
DWORD |
If this value is 1 (default), enables inclusion of manual references in Assembly structure and Where used dialogs. |
DisplayValidationAlerts |
DWORD |
If this value is 1, show a warning when opening a document in a read-only workflow state. If this value is 0, do not show a warning. Configured in the PowerUser Options dialog. |
DoNotSyncLWS4ShellMenu |
DWORD |
If this value is 1, the Local Workspace copy of the selected document will not be synchronized before retrieving related shell menu items. If this value is 0 (default), the document is synchronized. |
EnableAssignRoles |
DWORD |
If this value is 1, enables prompt to assign roles when creating a new work area. If this value is 0, disables prompt. 1 in PowerUser, 0 for Office client. If set to 0, automatically sets AssignRolesToNewWA to 0 internally. |
FlagsFor64bitExtensions |
DWORD |
Controls the loading of custom extensions by 64-bit client applications. If this value is 0, do not restrict extension loading. If this value is 1, do not load extensions. If this value is 2 (default), load extensions. |
GrayTextColor |
DWORD |
If non-zero, Windows text color is used instead of standard (gray) color for cleared controls. On closing of PowerUser, this value is set back for dimmed controls. Default is 0. Warning If this is set to anything but 0x808080, can affect other applications after PowerUser is closed. |
HighlightRecentDocs |
DWORD |
If this value is 1, highlight documents that are less than RecentDocsDateSpan days old. If this value is 0 (default), do not highlight. |
LastReleasedColor |
DWORD |
Color to display last released document names in the Show Revisions dialog. |
OfflineMode |
DWORD |
If this value is 1, use Web Access in offline mode. If this value is 0, do not use offline mode. |
OpenDialogsShowWA |
DWORD |
If this value is 1, show work areas in Open dialog. If this value is 0 (default), do not show work areas. Meridian only. |
QuickSearchAutoAppend |
DWORD |
If this value is 1 (default), enables the AutoComplete feature in Quick Find combo boxes. If this value is 0, feature is cleared. |
RebuildDirectoryStructure |
DWORD |
If this value is 1, sets Duplicator’s Rebuild directory structure option to Relative to each sub assembly. If this value is 0, sets it to Relative to the main assembly. |
RecentDocsDateSpan |
DWORD |
Age of documents in days to highlight. If this value is 0 (default), do not highlight. |
RedlinesWidth |
DWORD |
Width in pixels to display Meridian redlines in the Meridian viewer. Configured in the PowerUser Options dialog. |
ReleaseAllAssembly |
DWORD |
If this value is 0, release assembly documents only. If this value is 1, release assembly and all dependent documents. Configured in the PowerUser Options dialog. |
RowsToRetrieveForFind |
DWORD |
Maximum number of documents to show in Find results at one time. |
ShowOutOfScope |
DWORD |
If this value is 0, do not show the Explorer view inside work areas. If this value is 1, show the Explorer view. Configured in the PowerUser Options dialog. |
NEW
ShowRenditions |
DWORD |
Displays the rendition of the selected document in the viewer pane by default instead of the source file. This setting can also be configured in the PowerUser Options and Web Access Preferences dialogs. |
ThumbnailAutoUpdate |
DWORD |
If this value is 1 (default), enables automatic generation of thumbnails. If this value is 0, disables automatic generation. |
ThumbnailUpdateMode |
DWORD |
If this value is 1, generates thumbnails with viewer. If this value is 0 (default), use saved preview images when available. Configured in the PowerUser Options dialog. |
UpdateReferences |
DWORD |
If this value is 1 (default), enables Duplicator’s Update SolidWorks references option. |
UseImportedFrom |
DWORD |
Controls setting of the AMFSObjectPropertySet.ImportedFrom property during document import operations. Supported values are: 0 = Empty string This setting overrides the server registry key with the same name described in HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\Server. |
WebServicesMode |
DWORD |
If this value is 0 (default), CAD application links operate in Online mode. If this value is 1, CAD application links operate in Remote mode. |
WorkSpaceLocation |
DWORD |
Path to the Local Workspace folder. Supersedes HKEY_LOCAL_MACHINE\SOFTWARE\Cyco\AutoManager Meridian\CurrentVersion\Client\WorkSpaceLocation value. This setting is for online clients only. |
WorkSpaceNoUserName |
DWORD |
If this value is 1, the user account name is not appended to the Local Workspace folder name. If this value is 0 (default), the account name is appended. This is useful only if WorkSpaceLocation is also defined. This setting is for online clients only. |
WorkingColor |
DWORD |
Color to display document names in the view pane for documents under change. |
Copyright © 2000-2012 BlueCielo ECM Solutions |